DCT-11
TOPRO
85043110
Availability: | |
---|---|
TOPRO 100A DC immune Current transformer (DC immune CT) DCT-11 is used in single phase or three phase electricity meters, under the influence quantity with DC and even harmonics in AC current circuit. We adopted high quality amorphous alloy and nanocrystalline core for DC immunity Current transformer, with good linearity and high accuracy up to Class 0.2, Class 0.1.
Product Characteristics
1. It applied for single phase or three phase energy meters.
2. Adopted high quality amorphous alloy and nanocrystalline core, good ratio error and phase error performance.
3. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.
4. Encapsulated with epoxy resin with strong insulation ability.
5. DC immune current transformers (DCT) are used in electricity meters, under the influence quantity with DC and even harmonics in AC current circuit, the accuracy class up to 0.1, Conform to IEC62053-21.
6. Rosh compliance, CE certificated.
Product dimensions
100A DC immune Current transformer DCT-11 | Outline dimension |
|
Product datasheet
Model | 100 A DC immune Current transformer DCT-11 |
Rated primary current | 5 Amps |
Maximum primary current (Imax) | 100 Amps |
Secondary current (Output) | 2 mA |
Turn ratio | 1 : 2500 |
DC and even harmonics | Current for direct connected meters, Imax/√2 DC error should be less than ±3% when power factor=1.0, According to IEC 62053-21 |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nano crystalline and Amorphous |
Accuracy | 0.1 class |
ROSH compliance | Yes |
TOPRO 100A DC immune Current transformer (DC immune CT) DCT-11 is used in single phase or three phase electricity meters, under the influence quantity with DC and even harmonics in AC current circuit. We adopted high quality amorphous alloy and nanocrystalline core for DC immunity Current transformer, with good linearity and high accuracy up to Class 0.2, Class 0.1.
Product Characteristics
1. It applied for single phase or three phase energy meters.
2. Adopted high quality amorphous alloy and nanocrystalline core, good ratio error and phase error performance.
3. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.
4. Encapsulated with epoxy resin with strong insulation ability.
5. DC immune current transformers (DCT) are used in electricity meters, under the influence quantity with DC and even harmonics in AC current circuit, the accuracy class up to 0.1, Conform to IEC62053-21.
6. Rosh compliance, CE certificated.
Product dimensions
100A DC immune Current transformer DCT-11 | Outline dimension |
|
Product datasheet
Model | 100 A DC immune Current transformer DCT-11 |
Rated primary current | 5 Amps |
Maximum primary current (Imax) | 100 Amps |
Secondary current (Output) | 2 mA |
Turn ratio | 1 : 2500 |
DC and even harmonics | Current for direct connected meters, Imax/√2 DC error should be less than ±3% when power factor=1.0, According to IEC 62053-21 |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nano crystalline and Amorphous |
Accuracy | 0.1 class |
ROSH compliance | Yes |