DCT-05
TOPRO
85043110
Availability: | |
---|---|
TOPRO 200A 5000 turns DC immune Current transformer (DCT ) DCT-05 is used in India widely. We adopted high quality amorphous alloy and nanocrystalline core for DC immunity Current transformer, with good linearity and high accuracy up to Class 0.1, the Max Current reach to 240A.
Product Characteristics
1. It applied for smart meters.
2. Ratio 5000T, Imax reach to 240A.
3. Adopted high quality amorphous alloy and nanocrystalline core, good linearity and high precision.
4. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.
5. Conform to IEC62053-21.
6. Rosh compliance, CE certificated.
Product dimensions
200A DC immune Current transformer DCT-05 | Outline dimension |
|
Product datasheet
Model | 200 A DC immune Current transformer DCT-05 |
Rated primary current | 20 Amps |
Maximum primary current (Imax) | 200 Amps |
Out current | 4 mA |
Turn ratio | 1 : 5000 |
DC and even harmonics | Current for direct connected meters, Imax/√2 DC error should be less than ±3% when power factor=1.0, According to IEC 62053-21 |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nano crystalline and Amorphous |
Accuracy | 0.1 class |
ROSH compliance | Yes |
TOPRO 200A 5000 turns DC immune Current transformer (DCT ) DCT-05 is used in India widely. We adopted high quality amorphous alloy and nanocrystalline core for DC immunity Current transformer, with good linearity and high accuracy up to Class 0.1, the Max Current reach to 240A.
Product Characteristics
1. It applied for smart meters.
2. Ratio 5000T, Imax reach to 240A.
3. Adopted high quality amorphous alloy and nanocrystalline core, good linearity and high precision.
4. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.
5. Conform to IEC62053-21.
6. Rosh compliance, CE certificated.
Product dimensions
200A DC immune Current transformer DCT-05 | Outline dimension |
|
Product datasheet
Model | 200 A DC immune Current transformer DCT-05 |
Rated primary current | 20 Amps |
Maximum primary current (Imax) | 200 Amps |
Out current | 4 mA |
Turn ratio | 1 : 5000 |
DC and even harmonics | Current for direct connected meters, Imax/√2 DC error should be less than ±3% when power factor=1.0, According to IEC 62053-21 |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nano crystalline and Amorphous |
Accuracy | 0.1 class |
ROSH compliance | Yes |