Availability: | |
---|---|
Three phase polarized latching relay TP41-16, with Max. 100A switching current. The advantage of polarized latching relays is the pulse driven operation of some milliseconds, coil heating can be neglected. The relay is designed and manufactured in accordance to IEC 61810-1 as well as they meet the requirements of IEC 62055-31.
1. Both Single coil and double coil can be customized, the coil rated voltage can be 5VDC-48VDC;
2.Multi-layer blades, low temperature rise;
3.Low power consumption :2.5W for single coil and 5W for double coil;
4.Conform to IEC61810-1 and IEC62055-31 UC3 ;
5.Environmental protection (comply with ROSH) ;
6.Outline dimension:120mm×54mm×29.5mm.
Ordering information
Coil data
Rated Coil voltage | 6VDC, 9VDC, 12VDC, 24VDC, 48VDC |
Single coil power | 2.5W |
Double coil power | 5W |
Pulse width | 50ms Max |
Pulse time | <30 ms (At nominal voltage) |
contact data
Contact materials | AgSnO2 |
Contact arrangement | 3A(B) |
Contact resistance | 1.0mΩ Max(Test under 1A/6VDC) |
Max switching current | 100A |
Max switching voltage | 253VAC |
Max switching power | 25300VA |
Mechanical life | 1×105OPS |
Electrical life | 1×104OPS |
Standard winding(Coil voltage can be customized)
Nominal voltage(VDC) | Max operating voltage(VDC) | Coil resistance(1±10%)(Ω) |
Single winding | ||
6 | 4.8 | 14.4 |
9 | 7.2 | 32.4 |
12 | 9.6 | 57.6 |
24 | 19.2 | 230.4 |
48 | 38.4 | 921.60 |
Double winding | ||
6 | 4.8 | 7.2+7.2 |
9 | 7.2 | 16.2+16.2 |
12 | 9.6 | 28.8+28.8 |
24 | 19.2 | 150.2+150.2 |
48 | 38.4 | 460.8+460.8 |
Characteristics
Insulation resistance | 1000MΩ |
Dielectric strength between coil | 4000V 1 minute |
Dielectric strength between contact | 2000V 1 minute |
Creepage distance | 8mm |
Shock resistance | 147m/S2 |
Vibration resistance | 10-55HZ amplitude 1.5mm |
Ambient temperature | -40-+85℃ |
Weight | Approx.300g |
Construction | Dust protection |
Three phase polarized latching relay TP41-16, with Max. 100A switching current. The advantage of polarized latching relays is the pulse driven operation of some milliseconds, coil heating can be neglected. The relay is designed and manufactured in accordance to IEC 61810-1 as well as they meet the requirements of IEC 62055-31.
1. Both Single coil and double coil can be customized, the coil rated voltage can be 5VDC-48VDC;
2.Multi-layer blades, low temperature rise;
3.Low power consumption :2.5W for single coil and 5W for double coil;
4.Conform to IEC61810-1 and IEC62055-31 UC3 ;
5.Environmental protection (comply with ROSH) ;
6.Outline dimension:120mm×54mm×29.5mm.
Ordering information
Coil data
Rated Coil voltage | 6VDC, 9VDC, 12VDC, 24VDC, 48VDC |
Single coil power | 2.5W |
Double coil power | 5W |
Pulse width | 50ms Max |
Pulse time | <30 ms (At nominal voltage) |
contact data
Contact materials | AgSnO2 |
Contact arrangement | 3A(B) |
Contact resistance | 1.0mΩ Max(Test under 1A/6VDC) |
Max switching current | 100A |
Max switching voltage | 253VAC |
Max switching power | 25300VA |
Mechanical life | 1×105OPS |
Electrical life | 1×104OPS |
Standard winding(Coil voltage can be customized)
Nominal voltage(VDC) | Max operating voltage(VDC) | Coil resistance(1±10%)(Ω) |
Single winding | ||
6 | 4.8 | 14.4 |
9 | 7.2 | 32.4 |
12 | 9.6 | 57.6 |
24 | 19.2 | 230.4 |
48 | 38.4 | 921.60 |
Double winding | ||
6 | 4.8 | 7.2+7.2 |
9 | 7.2 | 16.2+16.2 |
12 | 9.6 | 28.8+28.8 |
24 | 19.2 | 150.2+150.2 |
48 | 38.4 | 460.8+460.8 |
Characteristics
Insulation resistance | 1000MΩ |
Dielectric strength between coil | 4000V 1 minute |
Dielectric strength between contact | 2000V 1 minute |
Creepage distance | 8mm |
Shock resistance | 147m/S2 |
Vibration resistance | 10-55HZ amplitude 1.5mm |
Ambient temperature | -40-+85℃ |
Weight | Approx.300g |
Construction | Dust protection |