TP-16
TOPRO
85043110
Availability: | |
---|---|
Three phase energy meter (poly phase meter) is used for commercial or industrial application. As in industries we have huge amount of current, so to protect it we will use current transformer. It will transfer the current to isolate energy meters from high current.
The current transformers TP-16 designed for high-precision, small phase error requirements for current, power, and electric energy monitoring and metering devices. They can be used for three phase energy meter and anti-tempering electric energy meters.
Product Characteristics
1. It applied for three phase energy meters.
2. Adopted high quality amorphous alloy and nanocrystalline core, good linearity and high precision.
3. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.
4. Encapsulated with epoxy resin with strong insulation ability.
5. Rosh compliance, CE certificated.
Product Dimensions
100 A Current transformer for three phase energy meters TP-16 | Outline dimension Unit: mm |
Product Datasheet
Model | 100 A Current transformer for three phase energy meters TP-16 |
Rated primary current | 10 Amps |
Maximum primary current (Imax) | 100 Amps |
Secondary current (Output) | 5 mA |
Turn ratio | 1 : 2000 |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nano crystalline |
Accuracy | 0.1 class or 0.2 Class |
ROSH compliance | Yes |
Three phase energy meter (poly phase meter) is used for commercial or industrial application. As in industries we have huge amount of current, so to protect it we will use current transformer. It will transfer the current to isolate energy meters from high current.
The current transformers TP-16 designed for high-precision, small phase error requirements for current, power, and electric energy monitoring and metering devices. They can be used for three phase energy meter and anti-tempering electric energy meters.
Product Characteristics
1. It applied for three phase energy meters.
2. Adopted high quality amorphous alloy and nanocrystalline core, good linearity and high precision.
3. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.
4. Encapsulated with epoxy resin with strong insulation ability.
5. Rosh compliance, CE certificated.
Product Dimensions
100 A Current transformer for three phase energy meters TP-16 | Outline dimension Unit: mm |
Product Datasheet
Model | 100 A Current transformer for three phase energy meters TP-16 |
Rated primary current | 10 Amps |
Maximum primary current (Imax) | 100 Amps |
Secondary current (Output) | 5 mA |
Turn ratio | 1 : 2000 |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nano crystalline |
Accuracy | 0.1 class or 0.2 Class |
ROSH compliance | Yes |