LZZBJ9-10A1G, B1,C1
TOPRO
Availability: | |
---|---|
High voltage current transformer LZZBJ9-10A1G, B1,C1
Product Description
LZZBJ9-10A1G,B1 and C1 type current transformer is epoxy resin cast indoor total working conditions of Protection or energy measurement with the power system with rated frequency 50Hz rated voltage of 10kV and below.
LZZBJ9-10A1G,B1 and C1 mounted in switch cabinets or other types of switchgear.
Features:
The current transformer is the pillar structure. Closed casting with epoxy resin, resistant to pollution and humidity. Also suitable for the tropics.
The transformer does not require special maintaince, just on a regular basis to remove surface dirt.
Current transformer with epoxy pouring full-closed, small size, good quailty, are suitable for any location, installed in any direction.
The meaning of the model
Technical data
Rated primary current | Accuracy class | Rated secondary output (VA) | 1 Second heat current | Rated dynamic current(KA) | |||
0.2S(0.2) | 0.5S(0.5) | 10P10 | |||||
5 | 0.2S/10P10 0.5S/10P10 0.2/10P10 0.5/10P10 | 10 | 10 | 15 | 0.75 | 1.8 | |
10 | 1.44 | 3.6 | |||||
15 | 2 | 5 | |||||
20 | 3 | 7.5 | |||||
25 | 4 | 10 | |||||
30 | 5 | 12.5 | |||||
40 | 6.3 | 15 | |||||
50 | 8.1 | 20 | |||||
75 | 16.2 | 40.5 | |||||
100 | 21.6 | 54 | |||||
150 | 36 | 80 | |||||
200 | 45 | 100 | |||||
300 | 45 | 100 | |||||
400 | 45 | 100 | |||||
500 | 63 | 130 | |||||
600 | 63 | 130 |
Outline dimensions and drawing (mm)
Please download the PDF file and refer to it
High voltage current transformer LZZBJ9-10A1G, B1,C1
Product Description
LZZBJ9-10A1G,B1 and C1 type current transformer is epoxy resin cast indoor total working conditions of Protection or energy measurement with the power system with rated frequency 50Hz rated voltage of 10kV and below.
LZZBJ9-10A1G,B1 and C1 mounted in switch cabinets or other types of switchgear.
Features:
The current transformer is the pillar structure. Closed casting with epoxy resin, resistant to pollution and humidity. Also suitable for the tropics.
The transformer does not require special maintaince, just on a regular basis to remove surface dirt.
Current transformer with epoxy pouring full-closed, small size, good quailty, are suitable for any location, installed in any direction.
The meaning of the model
Technical data
Rated primary current | Accuracy class | Rated secondary output (VA) | 1 Second heat current | Rated dynamic current(KA) | |||
0.2S(0.2) | 0.5S(0.5) | 10P10 | |||||
5 | 0.2S/10P10 0.5S/10P10 0.2/10P10 0.5/10P10 | 10 | 10 | 15 | 0.75 | 1.8 | |
10 | 1.44 | 3.6 | |||||
15 | 2 | 5 | |||||
20 | 3 | 7.5 | |||||
25 | 4 | 10 | |||||
30 | 5 | 12.5 | |||||
40 | 6.3 | 15 | |||||
50 | 8.1 | 20 | |||||
75 | 16.2 | 40.5 | |||||
100 | 21.6 | 54 | |||||
150 | 36 | 80 | |||||
200 | 45 | 100 | |||||
300 | 45 | 100 | |||||
400 | 45 | 100 | |||||
500 | 63 | 130 | |||||
600 | 63 | 130 |
Outline dimensions and drawing (mm)
Please download the PDF file and refer to it