T-02
TOPRO
85043110
Availability: | |
---|---|
In accordance with IEC62053-21 standards, the energy meter must be safeguarded from
external magnetic fields to prevent potential tampering. The TOPRO shielded Current transformer T-02
utilizes a custom metal shield (Material: DT4E) to protect against external magnetic fields,
offering the option of DC immunity.
Product Features
1. Suitable for electronic electricity meters, both single phase and three phase energy meters.
2. Utilizes high-quality amorphous alloy and nanocrystalline core for excellent linearity and precision.
3. CT case made from flame retardant PBT materials, providing strong mechanical and electrical properties.
4. Epoxy resin encapsulation ensures high insulation capabilities.
5. DC immune current transformers (DCT) can be used in electricity meters, meeting IEC62053-21 and ANSI C12.20
standards.
6. Metal shield included to protect CT from external magnetic fields up to 300mT.
7. RoHS compliant and CE certified.
Product Dimensions
60 A DC immune Current transformer against external magnetic field T-02 | Outline dimension Unit: mm |
Product Datasheet
Model | 60 A Current transformer against external magnetic field T-02 |
Rated primary current | 5 Amps |
Maximum primary current (Imax) | 60 Amps |
Secondary current (Output) | 2 mA |
Turn ratio | 1 : 2500 |
DC and even harmonics | Current for direct connected meters, Imax/√2 DC error should be less than ±3% when power factor=1.0, According to IEC 62053-21 |
Against external magnetic field | 300 mT |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nano crystalline and Amorphous |
Accuracy | 0.1 class or 0.2 Class |
ROSH compliance | Yes |
In accordance with IEC62053-21 standards, the energy meter must be safeguarded from
external magnetic fields to prevent potential tampering. The TOPRO shielded Current transformer T-02
utilizes a custom metal shield (Material: DT4E) to protect against external magnetic fields,
offering the option of DC immunity.
Product Features
1. Suitable for electronic electricity meters, both single phase and three phase energy meters.
2. Utilizes high-quality amorphous alloy and nanocrystalline core for excellent linearity and precision.
3. CT case made from flame retardant PBT materials, providing strong mechanical and electrical properties.
4. Epoxy resin encapsulation ensures high insulation capabilities.
5. DC immune current transformers (DCT) can be used in electricity meters, meeting IEC62053-21 and ANSI C12.20
standards.
6. Metal shield included to protect CT from external magnetic fields up to 300mT.
7. RoHS compliant and CE certified.
Product Dimensions
60 A DC immune Current transformer against external magnetic field T-02 | Outline dimension Unit: mm |
Product Datasheet
Model | 60 A Current transformer against external magnetic field T-02 |
Rated primary current | 5 Amps |
Maximum primary current (Imax) | 60 Amps |
Secondary current (Output) | 2 mA |
Turn ratio | 1 : 2500 |
DC and even harmonics | Current for direct connected meters, Imax/√2 DC error should be less than ±3% when power factor=1.0, According to IEC 62053-21 |
Against external magnetic field | 300 mT |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nano crystalline and Amorphous |
Accuracy | 0.1 class or 0.2 Class |
ROSH compliance | Yes |