Single phase energy meter is used for home appliances. TOPRO current transformers SP-03 is designed for high-precision, small phase error requirements for current, power, and electric energy monitoring and metering devices. They can be used for single phase energy meter and anti-tempering electric energy meters.
Product Characteristics
1. It applied for single phase energy meter.
2. current transformer ratio: 2000:1.
3. .Adopted high quality nanocrystalline core, good linearity and high precision, accuracy class 0.2.
4. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.
5 .Encapsulated with epoxy resin with strong insulation ability.
6. Rosh compliance, CE certificated.
Product dimensions
60A AC Current transformer 2000:1 SP-03 | Outline dimension Unit: mm |
|
Product datasheet
Model | Current transformer for single phase energy meter SP-03 |
Rated primary current | 5 Amps |
Maximum primary current (Imax) | 60 Amps |
Secondary current (Output) | 2.5 mA |
Turn ratio | 1 : 2000 |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nanocrystalline |
Accuracy | 0.1 class or 0.2 Class |
Encapsulated | Epoxy resin |
ROSH compliance | Yes |
Single phase energy meter is used for home appliances. TOPRO current transformers SP-03 is designed for high-precision, small phase error requirements for current, power, and electric energy monitoring and metering devices. They can be used for single phase energy meter and anti-tempering electric energy meters.
Product Characteristics
1. It applied for single phase energy meter.
2. current transformer ratio: 2000:1.
3. .Adopted high quality nanocrystalline core, good linearity and high precision, accuracy class 0.2.
4. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.
5 .Encapsulated with epoxy resin with strong insulation ability.
6. Rosh compliance, CE certificated.
Product dimensions
60A AC Current transformer 2000:1 SP-03 | Outline dimension Unit: mm |
|
Product datasheet
Model | Current transformer for single phase energy meter SP-03 |
Rated primary current | 5 Amps |
Maximum primary current (Imax) | 60 Amps |
Secondary current (Output) | 2.5 mA |
Turn ratio | 1 : 2000 |
Operating temp. | -40° C - 70° C |
Storage Temp | -40° C -85° C |
Core material | Nanocrystalline |
Accuracy | 0.1 class or 0.2 Class |
Encapsulated | Epoxy resin |
ROSH compliance | Yes |